Specifications
Best Operating Frequency : 112kHz+/- 4%
Min. Transmit Sensitivity: 170dB re 1 μPa/V at 1m
at best transmit frequency
Min. Receive Sensitivity:-169 dB re 1V/μPa
 at best receive frequency
Min. Parallel Resistance: 420Ω +/- 30%
Minimum sensor range: 15cm*
Maximum sensor range: 7m*
Free(1kHz) Capacitance:1000pF +/- 200pF
Beam width (-3dB full angle): 12° +/- 2°
Maximum Driving Voltage:800Vpp
(2% duty cycle tone burst)
Operating Temperature:-40° C to 90°C
Weight : 20g

Materials:
Housing: Glass filled polyester
Acoustic Window: Glass reinforced epoxy
All specifications typical at 22° C and subject
to change without notice.